ETANORM SYT

Horizontal volute casing pump in back pull-out design, single-stage, with ratings and dimensions to EN 733, radially split volute casing with integrally cast pump feet, replaceable casing wear rings, closed radial impeller with multiply curved vanes, single mechanical seal to EN 12756, double mechanical seal to EN 12756, drive-end bearings: rolling element bearings, pump-end bearings: plain bearings, with magnetless KSB SuPremE motor (exception: motor sizes 0.55 kW / 0.75 kW with 1500 rpm are designed with permanent magnets) of efficiency class IE4/IE5 and PumpDrive variable speed system; ATEX-compliant version available.

es000790-etanorm-syt

Technical specification

Function Pump
Connection type Flange
Drive concept With electric actuator
Max. flow rate 754 m3/h
Min. flow rate 1.5 m3/h
Max. head 102 m
Min. head 2 m
Mains frequency 50 Hz, 60 Hz
Mains voltage 400 V, 460 V
Nominal pressure PN 16
Max. allowed working pressure 16 bar
Suction behaviour Non-self-priming
Maximum allowable fluid temperature 350 °C
Minimum allowable fluid temperature -30 °C

Design

Horizontal, long-coupled volute casing pump in back pull-out design with ratings and main dimensions to EN 733, single-stage, with replaceable casing wear rings. Design to ATEX.