Pumping clean or aggressive liquids not chemically or mechanically aggressive to the pump materials in water supply systems, cooling circuits, swimming pools, fire-fighting systems, irrigation systems, drainage systems, heating systems, air-conditioning systems, spray irrigation systems.

Technical specification

Function Pump
Connection type Flange
Drive concept With electric actuator, Combustion engine
Max. flow rate 1368 m3/h
Min. flow rate 1.5 m3/h
Max. head 160 m
Min. head 2 m
Mains frequency 50 Hz, 60 Hz
Mains voltage 400 V, 460 V, 220 V, 230 V, 240 V, 380 V, 415 V, 500 V, 575 V, 660 V, 690 V
Casing material EN-GJL-250/A48 CL 35B, CC480K-GS/B30 C90700, 1.4408/A743CF8M, EN-GJS-400-15/A536 GR 60-40-18
Nominal pressure PN 16, PN 10, CL 150, CL 125
Max. allowed working pressure 16 bar
Suction behaviour Non-self-priming
Minimum allowable fluid temperature 140 °C
Minimum allowable fluid temperature -30 °C

Design

Horizontal volute casing pump, single-stage, with ratings and main dimensions to EN 733, long-coupled, back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings, with motor-mounted variable speed system. With KSB SuPremE, a magnetless synchronous reluctance motor of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.