The solid casing split flange at the upper and lower casing part ensures reliable and trouble-free sealing with Liquid Gasket between the upper and lower casing halves.

Single-stage, horizontal, with axially spilt volute casing, with integrally cast pump feet and double-entry radial impeller. Nominal diameter of the discharge nozzles from 80 mm to 350 mm

Technical specification

Connection type Flange
Drive concept Combustion engine, With electric actuator
Max. flow rate 3200 m3/h
Min. flow rate 13 m3/h
Max. head 90 m
Min. head 5 m
Mains frequency 50 Hz, 60 Hz
Mains voltage 415 V
Casing material IS 210 GR FG260
Nominal pressure PN 10
Suction behaviour Non-self-priming
Maximum allowable fluid temperature 80 °C
Minimum allowable fluid temperature 0 °C

Design

Single-stage volute casing pump in in-line design, with magnetless KSB SuPremE motor of efficiency class IE4/IE5 and PumpDrive variable speed system; pump shaft and motor shaft are rigidly connected. With KSB SuPremE, a magnetless synchronous reluctance motor of efficiency class IE4/IE5 to IEC TS 60034-30-2:2016, for operation with the KSB PumpDrive 2 or KSB PumpDrive 2 Eco variable speed system without rotor position sensors. Motor mounting points in accordance with EN 50347, envelope dimensions in accordance with DIN V 42673 (07-2011). ATEX-compliant version available.